Home > Products > Reverse Osmosis System > Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water
              Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water
              • Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking WaterNanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water
              • Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking WaterNanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water
              • Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking WaterNanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water
              • Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking WaterNanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water

              Nanofiltration VNF- 1812 Vontron NF Technology for Healthy Drinking Water

              Brief IntroductionApplicable to various small-sized drinking systems, such as home drinking water purifiers, mineralized drinking fountain, etc., the residential 1812-type and 2012-type NF elements are designed for removing from water various organics, microbes, viruses and most metallic ions with t......

              Send Inquiry

              Product Description

              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water
              Brief Introduction

              Applicable to various small-sized drinking systems, such as home drinking water purifiers, mineralized drinking fountain, etc., the residential 1812-type and 2012-type NF elements are designed for removing from water various organics, microbes, viruses and most metallic ions with two or higher valence while retaining part of the sodium, potassium, calcium and magnesium ions, etc., thus improving the mouthfeel of purified water and maintaining the content of mineral nutrition.
               
              ModelSolution TypeAverage Permeate
              GPD(m3/d)
              Stable Rejection
              %
              VNF-1812
               
              NaCl
               
              100 (0.38)
               
              30±10
               
              CaCl2
               
              >85
               
              VNF-2012
               
              NaCl
               
              120 (0.45)
               
              30±10
               
              CaCl2
               
              >85
               
              VNF-3012
               
              NaCl
               
              400(1.51)
               
              30±10
               
              CaCl2
               
              >85
               
              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water
               
              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water

              Precautions for Use of Dry-type Membrane Elements
              Storage of Dry-type Membrane Elements
              1. The membrane elements must be stored in cool and dry place, and shall not be exposed to direct sunlight.
              2. The dry-type elements shall be stored in the place with temperature not higher than 45, below which temperature the elements can be stored for unlimited period.
              General Information of Dry-type Membrane Elements
              1. The dry-type membrane elements shall be always kept in wet condition once been moistened.
              2. Only after being operated for at least 6 hours can the dry-type membrane elements be disinfected with formaldehyde.
              3. The dry-type membrane elements work under the Operating Limits and Conditions and design guide identical to the wet-type elements of same specifications.
              4. Once a dry-type membrane element is moistened to become a wet-type element, it shall be disposed of according to the methods of storage, preservation and cleaning indicated in this Manual corresponding to equivalent wet-type membrane element.
              5.The initial adjustment and running of RO system shall be conducted in accordance with the procedures indicated in "Chapter 4 - Operation and Maintenance of RO System", and the filtered water and rejected water produced in the first one hour shall be discarded.

              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water


              Vontron Membrane Technology Co., Ltd. is specialized in R&D, manufacture and technical service of RO and NF membrane elements. Owning the core technology and capability for fabrication of membrane sheet, Vontron is the biggest professional manufacturer of compound RO membranes in China, and is the provider of system design and applied service with powerful technical support.

              Vontron has advanced automatic membrane production line, which achieves the integrated production of ultrafiltration base membrane and separation layer, improves the production efficiency, independently designs and develops the scraping integrated automatic production line achieves a great breakthrough in production capacity through speed control. The automatic rolling process of membrane element could precisely control and ensure the accurate membrane area, uniform configuration and stable structure of membrane element.


              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking WaterNanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water
              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water

              Nanofiltration VNF-1812 Vontron NF Technology for Healthy Drinking Water

              Related Category

              Send Inquiry

              Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
              Click Refresh verification code

              Leave Your Message

              • Click Refresh verification code